The ZWGC808 is a high-performance gas chromatograph for qualitative and quantitative analysis of permanent gases, volatile organic compounds, and trace-level components.
With precise temperature control, flexible detector configurations, and Ethernet-based data management, it supports reliable analysis across petroleum, chemical, environmental, food, pharmaceutical, and research laboratories.
Product Overview
The ZWGC808 Gas Chromatograph Analyzer separates and identifies sample components according to their different retention times in a chromatographic column. It supports qualitative analysis based on retention time and quantitative analysis using peak height or peak area.
With multiple injector and detector options, programmable column oven control, high-sensitivity signal acquisition, and network-ready data processing, the instrument can be configured for routine testing, trace analysis, and complex multi-component sample analysis.
Functions and Value:
-
High-Efficiency Gas Chromatography: Delivers rapid separation and high analytical efficiency for permanent gases, volatile organic compounds, petroleum samples, and other suitable substances.
-
Multi-Detector Configuration: Supports FID, TCD, ECD, FPD, NPD, HID, and PDECD detectors. Up to four detectors can be installed simultaneously for comprehensive analysis of complex samples.
-
Flexible Injection Options: Compatible with packed-column injectors, capillary injectors, six-port gas valves, and autosampler configurations for different sample types and testing workflows.
-
Precise Temperature Control: Provides eight independent temperature control channels and programmable heating for the injection port, column oven, detectors, and auxiliary components.
-
Advanced Temperature Programming: Supports up to 99 programmed heating stages, expandable to 999 stages, helping improve the separation of complex mixtures with different boiling points.
-
Fast Column Oven Response: The large-capacity oven and automatic rear-door mechanism support rapid heating and cooling, reducing thermal equilibrium time between analyses.
-
High-Sensitivity Detection: Optional detector configurations support macro-, micro-, and trace-level analysis, with suitable detectors capable of detecting components from ppm to ppb concentrations.
-
Real-Time Instrument Monitoring: The 7-inch touchscreen displays gas flow, pressure, temperature, detector status, and real-time signal curves, helping operators monitor the complete analytical process.
-
Network Data Management: Ethernet, Wi-Fi, and instrument hotspot connectivity support workstation communication, laboratory network integration, data transfer, and remote instrument monitoring.
-
Laboratory System Integration: Built-in MODBUS/TCP, HTTP, and MQTT protocols support data exchange with LIMS, DCS, IoT platforms, and other laboratory management systems.
-
Cross-Platform Operation: The workstation supports mainstream Windows systems, domestic operating systems, and Android tablets for flexible data processing and instrument control.
-
Modular Maintenance: The modular design allows independent removal and servicing of key components, helping reduce maintenance time and instrument downtime.
Technical Details
| Parameter | Specification |
|---|---|
| Model | ZWGC808 |
| Display | 7-Inch HD Capacitive Touchscreen |
| Temperature Control Channels | 8 Independent Channels |
| Temperature Range | Ambient +5°C to 450°C |
| Temperature Setting Resolution | 0.01°C |
| Temperature Control Accuracy | ±0.01°C |
| Programmable Heating Stages | 99 Stages, Expandable to 999 Stages |
| Maximum Heating Rate | 120°C/min |
| Injector Options | Packed Column, Capillary, Six-Port Gas Valve, Autosampler |
| Detector Options | FID, TCD, ECD, FPD, NPD, HID, PDECD |
| Maximum Detector Configuration | Up to 4 Detectors |
| Pressure Sensor Channels | Up to 20 Channels |
| External Events | 12 External Events |
| Communication Interfaces | Ethernet, Wi-Fi, Instrument Hotspot |
| Data Conversion | 24-Bit Analog-to-Digital Conversion |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Recommended Operating Temperature | 5°C to 35°C |
| Ambient Humidity | ≤ 85% RH |
| Required Gas Purity | Up to ≥99.999%, depending on detector and gas type |
Model Selection Guide
| Item NO. | Max Current | Measuring Range | Main Features | Recommended Application |
|---|---|---|---|---|
| GDZR-10A | 10A | 100μΩ - 20KΩ | Portable, built-in discharge alarm | Small to medium distribution transformers |
| GDZR-20A | 20A | 10μΩ - 10KΩ | High-speed testing, heat dissipation | Medium-sized power transformers |
| GDZR-40A | 40A | 1μΩ - 2KΩ | Dual-channel measurement, high current | Large-scale power transformers |
| GDZR-40A | Three-Phase 10A | 100μΩ - 10KΩ | Three-phase simultaneous measurement | Yn-type transformers, time-saving |
Recent Work



Parts List
| Item NO. | Max Current | Measuring Range | Main Features | Recommended Application |
|---|---|---|---|---|
| GDZR-10A | 10A | 100μΩ - 20KΩ | Portable, built-in discharge alarm | Small to medium distribution transformers |
| GDZR-20A | 20A | 10μΩ - 10KΩ | High-speed testing, heat dissipation | Medium-sized power transformers |
| GDZR-40A | 40A | 1μΩ - 2KΩ | Dual-channel measurement, high current | Large-scale power transformers |
| GDZR-40A | Three-Phase 10A | 100μΩ - 10KΩ | Three-phase simultaneous measurement | Yn-type transformers, time-saving |
Product Video
Discover how the ZWJD111E BDV Tester simplifies insulating oil diagnostics.

Certificate
Frequently Asked Questions
Contact our engineers for technical support and application guidance.
The ZWGC808 is suitable for permanent gases, volatile organic compounds, petroleum samples, chemical products, environmental samples, food-related compounds, and other substances compatible with gas chromatography.
Optional detectors include FID, TCD, ECD, FPD, NPD, HID, and PDECD. Up to four detectors can be installed simultaneously for multi-component and multi-selectivity analysis.
Yes. The instrument has eight independent temperature control channels and supports up to 99 programmed heating stages, expandable to 999 stages. The column oven temperature can be adjusted from ambient +5°C to 450°C.
Yes. The instrument supports Ethernet, Wi-Fi, and an integrated hotspot. Its MODBUS/TCP, HTTP, and MQTT protocols support communication with workstations, LIMS, DCS, and IoT-based laboratory management systems.
Related Products