Karl Fischer Water Content Tester

Using Karl Fischer coulometric titration, automatic electrolytic current control, and a 32-bit embedded microcontroller, 

it delivers fast, reliable, and repeatable moisture analysis for power, petroleum, chemical, pharmaceutical, railway, pesticide, and environmental laboratories.

0.1 µg Sensitivity
Automatic Current Control
Touchscreen
Get A Quote
Product Function
Technical Details
Model Selection Guide
Recent Work
Parts List
Product Video
Certificate
FAQ

Product Overview

The ZWWS101 is designed for accurate determination of trace water content in a wide range of industrial and laboratory samples. Its Karl Fischer coulometric analysis generates iodine electrochemically and calculates the water content according to Faraday’s law, eliminating the need for manual titrant volume measurement.

With automatic endpoint control, blank-current compensation, digital sample parameter entry, and automatic result recording, the tester helps laboratory and maintenance personnel reduce manual calculation errors and improve testing efficiency. It is suitable for quality control, incoming material inspection, production monitoring, and preventive maintenance applications.

 

Instrument features:

  1. Utilizing 32 bit embedded microcontroller processor as the master control coreand embedded mini operatingsystem.
  2. Bestableand reliable because of constant pressure detection, high precision and rapid measuring speed.
  3. Simpleoperationand convenient digital calculation due to color touch screen and full digital keyboard.
  4. Four calculation formulas are included, which can meet the different requirementof customer.
  5. Miniaturethermalprinter with time record make searching more convenient.
  6. New profile is designed according to the
  7. Creative and optimal operating software will bring a different touch experiencefor you.

Technical Details

ParameterSpecification
Titration methodCoulometric titration(Coulomb analysis)
DisplayColor LCD touch screen
Electrolytic current control0~400mA automatic control
Measurement scope0 ug~200mg
Sensitive valve0.1µg H2O
Accuracy10µg~1000µg±3µg; More than 1mg but not greater than 0.3%
Power supply220V±10% 50Hz
Power< 40W
Ambient temperature5~40℃
Ambient humidity≤ 85%
External dimension340×295×155mm
WeightAbout 5.5kg

Model Selection Guide

Item NO.Max CurrentMeasuring RangeMain FeaturesRecommended Application
GDZR-10A10A100μΩ - 20KΩPortable, built-in discharge alarmSmall to medium distribution transformers
GDZR-20A20A10μΩ - 10KΩHigh-speed testing, heat dissipationMedium-sized power transformers
GDZR-40A40A1μΩ - 2KΩDual-channel measurement, high currentLarge-scale power transformers
GDZR-40AThree-Phase 10A100μΩ - 10KΩThree-phase simultaneous measurementYn-type transformers, time-saving

Recent Work

ZHIWEI Karl Fischer Water Content Tester
Recent Work
总字符请不要超出130Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur eu fugiat nulla pariatur.
ZHIWEI Karl Fischer Water Content Tester
Recent Work
总字符请不要超出130Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur eu fugiat nulla pariatur.
ZHIWEI Karl Fischer Water Content Tester
Recent Work
总字符请不要超出130!!Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur eu fugiat nulla pariatur.

Parts List

Item NO.Max CurrentMeasuring RangeMain FeaturesRecommended Application
GDZR-10A10A100μΩ - 20KΩPortable, built-in discharge alarmSmall to medium distribution transformers
GDZR-20A20A10μΩ - 10KΩHigh-speed testing, heat dissipationMedium-sized power transformers
GDZR-40A40A1μΩ - 2KΩDual-channel measurement, high currentLarge-scale power transformers
GDZR-40AThree-Phase 10A100μΩ - 10KΩThree-phase simultaneous measurementYn-type transformers, time-saving

Product Video

Discover how the ZWJD111E BDV Tester simplifies insulating oil diagnostics.

Get A Quote

Certificate

Frequently Asked Questions

Need more information about the ZWWS101? Contact our engineers for expert technical support and application guidance.

Get A Quote

The ZWWS101 uses Karl Fischer coulometric titration. Iodine is generated electrochemically in the titration cell, and the instrument determines the water content according to the electrical charge consumed during the reaction. This method is suitable for trace moisture analysis in a wide range of samples.

The measurement range is 0 µg to 200 mg, with a sensitivity of 0.1 µg H₂O. The stated accuracy is ±3 µg for measurements from 10 µg to 1000 µg, and not greater than ±0.3% for measurements above 1 mg.

Yes. The ZWWS101 can measure liquid samples directly through the sample port. Solid samples can be introduced with a suitable solid sample injector or water evaporator. Gas samples can be tested with a compatible gas injector. For gas measurement, the manual specifies approximately 150 mL of electrolytic solution in the anode chamber and a stable gas flow of approximately 100 mL/min.

Before sample testing, the reagent must reach a normal and stable condition, and the blank current should be minimized. The ZWWS101 monitors blank-current-related values and can store the blank current caused by moisture absorbed from the air or titration cell. 

Proper sealing, drying, reagent adjustment, and stable stirring are also important for obtaining reliable low-moisture results. Because the Karl Fischer reagent may contain odorous, toxic, and flammable components, reagent handling should be performed in a well-ventilated area or fume hood.

Related Products

Get a Quote within 24H

Contact Form Demo

Download Catalogue!

Download our catalog to check all of our products and data sheet.

Download Form

Get Instant Quote Now!

Contact Form Demo

Tagline

Lorem ipsum

Lorem ipsum dolor sit amet consectetur. Orci sollicitudin viverra mauris ac sed lectus morbi egestas. Urna massa ante in bibendum bibendum urna turpis eu.

Contact Form Demo

Leave Your Message Here

Aliqua id fugiat nostrud irure ex duis ea quis id quis ad et.

Contact Form Demo

contact us

We typically respond within 2 hours on business days.

Contact Form Demo